PerkinElmer

进样系统

OF

准确,可重复的结果源于完美的进样系统,这就是为什么我们投入大量资源用于测试和校验我们的进样系统配件 - 以确保您在仪器的整个生命周期,每次都能获得最好的结果。 我们提供多种进样系统,包括:

  • 紫外进样系统
  • 红外进样系统
  • 顶空进样系统
  • 其他

  • 产品与服务

  • 资源,活动及更多信息

缩小结果
产品类型
  • Accessories (108)
  • Consumables (17)
  • Service Parts (7)
材料
  • Ge (10)
  • ZnSe (9)
  • AMTIR (6)
  • Diamond/ZnSe (1 Reflection) (6)
  • Diamond/ZnSe (9 Reflection) (5)
  • Diamond/ZnSe (3 Reflection) (4)
  • Ge (1 Reflection) (3)
  • KRS-5 (1 Reflection) (3)
  • KRS-5 (2)
  • Coated ZnSe (2)
型号兼容
  • Frontier (38)
  • Spectrum One (27)
  • Spectrum 400 (26)
  • Spectrum 100 (26)
  • Spectrum 65 (25)
  • Spectrum Two (12)
  • LAMBDA 750 (6)
  • LAMBDA 950 (6)
  • LAMBDA 650 (6)
  • LAMBDA 850 (6)
  • LAMBDA 1050 (6)
  • NIRM (3)
  • NIRA II (3)
  • Spectrum GX (1)
  • Spectrum One/100/400/65/Frontier (1)
  • Spectrum BX/RX (1)
产品品牌名称
  • Clarus (1)
  • Spectrum Two N (1)
产品组
  • Top Plates (24)
  • Thermostatting Accessory (11)
  • HATR Accessory (9)
  • Desolvation Accessory (6)
  • Miracle Accessory (5)
  • Optical Bench (5)
  • Polarizer (4)
  • UATR Accessory (4)
  • Sampling System (3)
  • Top Plate Accessory (3)
  • NIR Accessory (3)
  • Diffuse Reflectance Accessory (2)
  • Depolarizers (2)
  • UATR Polarization Accessory (2)
  • Sample Holder (1)
  • Polarization Accessory (1)
  • Volatiles Cover (1)
  • IR Specular Reflectance Set (1)
  • Variable-Angle Accessory (1)
  • Total Emission Accessory (1)
  • ATR Pressure Arm (1)
  • Clamp Assemblies and Replacement Parts (1)
  • Pressure Gauge (1)
  • Fiber Optic Accessory (1)
  • NIRM Accessory (1)
  • Imaging Accessory (1)
  • Variable Angle Accessory (1)
  • Fixed Angle Accessory (1)
  • Silver Gate (1)
  • Powder Press (1)
  • Light Shield (1)
  • Heatable Transmission Accessory (1)
  • GladiATR Diamond (1)
技术类型
  • ATR (53)
  • Diffuse Reflectance (9)
  • Specular Reflectance (3)
  • FT-IR (1)
  • Fluorescence Sampling (1)
  • Fiber Optics (1)

"进样系统" 1-50132 产品与服务

每页
PerkinElmer

6-Position Peltier Controlled Cell Changer W/O Heat Ref. for LAMBDA 365

This product is useful for thermal denaturation, kinetics, and other applications where precise temperature control is necessary. It accommodates up to 6 samples for automated measurement. It has full software control of temperature and stirring. It contains a built-in radiator that maintains temperature of circulating coolant. It includes a Peltier controller with 6-Position Multi-Cell Holder and 2 temperature probes.
PerkinElmer

6-Position Peltier Controlled Cell Changer W/Heat Ref. for LAMBDA 365

This product is useful for thermal denaturation, kinetics, and other applications where precise temperature control is necessary. It accommodates up to 6 samples for automated measurement. It has full software control of temperature and stirring. It contains a built-in radiator that maintains temperature of circulating coolant. It includes a Peltier controller, a 6-Position Multi-Cell Holder (with heated reference) and 2 temperature probes.
PerkinElmer

Single Cell Peltier Holder w/o Heat Ref. for LAMBDA 365

Useful for thermal denaturation, kinetics, and other applications where precise temperature control is necessary. It has full software control of temperature and stirring for 1 sample. It contains a Peltier controller and single cell holder.
8-Position Multicell Holder for LAMBDA 365

8-Position Multicell Holder for LAMBDA 365

Accommodates any standard 10 mm cells; up to 8 samples.
Near Infrared Reflectance Module (NIRM) for Spectrum Two N FT-NIR

Near Infrared Reflectance Module (NIRM) for Spectrum Two N FT-NIR

The Near Infrared Reflectance Module for the Spectrum Two N FT-NIR provides a convenient and sensitive method for analyzing opaque or highly scattering solid samples such as pharmaceuticals, food products, soap powders, coal, clay, soil, paper, painted surfaces, polymer foam, and catalysts.
Spectrum Two N with NIRM accessory and optional Sample Vial Holder

Sample Vial Holder

The Sample Vial Holder for use with the Near-Infrared Reflectance Module (NIRM) and Near Infrared Reflectance Accessory (NIRA II) securely holds and aligns vials on the accessory window.
PerkinElmer

Fiber Coupling Module-Req./ Inc.* for LAMBDA 465

Used for measuring liquid samples; intended for hazardous samples. Includes N4101048, a transmission dip probe and a 10 mm pathlength tip. Easy to clean.
Peltier Control Single Cell w/o Heat Ref for LAMBDA 465

Peltier Control Single Cell w/o Heat Ref for LAMBDA 465

This is useful for thermal denaturation, kinetics, and other applications where precise temperature control is necessary. Full software control of temperature and stirring for 1 sample. Included is a Peltier controller with single cell holder and 2 temperature probes.
Spectrum Two N with NIRM accessory and optional Sample Spinner

60 mm Sample Spinner

The Sample Spinner for use with the Near-Infrared Reflectance Module (NIRM) and Near-Infrared Reflectance Accessory (NIRA II) provides representative sampling of non-homogenous samples.
Fiber Coupling Module-Req./Not Inc.* for LAMBDA 365

Fiber Coupling Module-Req./Not Inc.* for LAMBDA 365

Fiber Optic Probe Module Only for L365. When combined with Fiber Optic Probe it can be used for measuring liquid samples; intended for hazardous samples.
Peltier Temperature Controller (without Cell) for LAMBDA 265

Peltier Temperature Controller (without Cell) for LAMBDA 465

Comes with internal liquid cooling system and N2 purge gas capability, magnetic stirrer control, and emergency power off switch.
Water Jacketed Automatic Referencing Stage for LAMBDA 465

Water Jacketed Automatic Referencing Stage for LAMBDA 465

Accommodates any standard 10 mm cells 2-Position for reference and sample. Unique accessory provides long term stability for monitoring kinetics reactions. Use recirculating liquid to control the temperature of a sample and reference solution for simultaneous analysis.
Spectrum Two N with NIRM accessory and optional Sample Spinner

100 mm Sample Spinner

The Sample Spinner for use with the Near-Infrared Reflectance Module (NIRM) and Near-Infrared Reflectance Accessory (NIRA II) provides representative sampling of non-homogenous samples.
PerkinElmer

Peltier Control Multi-Cell (8) W/ Heated Ref for LAMBDA 465

Useful for thermal denaturation, kinetics, and other applications where precise temperature control is necessary. It accommodates up to 8 samples for automated measurement. Full software control of temperature and stirring, and a built- in radiator that maintains temperature of circulating coolant. Included is a Peltier controller, 8-position multi-cell holder (with heated reference) and 2 temperature probes. Can be configured to 7 sample + 1 heated reference.
Spectrum Two N HTM

Heatable Transmission Module (HTM) for Spectrum Two Platform

The Heatable Transmission Module (HTM) for the Spectrum Two platform (including both the Spectrum Two FT-IR and Spectrum Two N FT-NIR) allows for easy elevated temperature measurements on samples in the Mid-IR or Near-IR regions of the spectrum, the module accepting fixed pathlength sealed.
PerkinElmer

Diffuse Reflectance Accessory for LAMBDA 465

Used for measuring the diffuse reflectance (SCE) and color analysis for solid and powder samples. It has a spectral range of 270~1000 nm (UV and Visible), and a port size of 10.00 and 5.00 mm (selectable). Included is a Xenon Lamp (150W), and a White Standard (1 each).

Apex IR-FAST for NexION

Apex IR-FAST with integrated CTFE Fluoropolymer high-flow valve for PE NexION ICPMS. Includes one PFA-100 nebulizer, one PFA-ST nebulizer and adapter to NexION.

Apex Q-FAST for NexION

Apex Q-FAST with integrated CTFE Fluoropolymer high-flow valve for PE NexION ICPMS, cassette torch mount. Includes one PFA-100 nebulizer, one PFA-ST nebulizer and adapter to NexION.
*Fiber Optic Probe for LAMBDA 465

Fiber Optic Probe for LAMBDA 465

Replacement Fiber Optic Probe and a 10 mm pathlength tip for the N4104012 or N4101013 Fiber Optic Probe Modules.

Premium HATR Flat Top Plate, 45° Ge

This Flat Top Plate features a 45° Germanium (Ge) crystal, for use with the PerkinElmer Premium HATR accessories.

Premium HATR Flat Top Plate, 60° ZnSe

This Flat Top Plate features a 60° Zinc Selenide (ZnSe) crystal, for use with the PerkinElmer Premium HATR accessories.

UATR Accessory for Spectrum One

The Universal ATR is an excellent general accessory for the analysis of solids and liquids, producing high quality spectra through the use of a pressure arm, allowing for good contact of the sample with the diamond/ZnSe crystal.
PerkinElmer

1+1 Peltier System

Includes the Peltier Single Sample Accessory (B2000159) for the sample position and the Single Reference Accessory (B0510412) for the reference position. Also included are a reference position cover, power supply, power cables, and User's Guide.

Premium HATR Trough Top Plate, 60° AMTIR

This Trough Top Plate features a 60° AMTIR (As/Se/Ge) crystal, for use with the PerkinElmer Premium HATR accessories.
PerkinElmer

Rotating Sample Holder for Frontier NIRA

The Rotating Sample Holder for the Sample Compartment NIRA is designed to enhance reproducibility of measurements by enabling collection of a representative spectrum of an inhomogenous sample.

Top Plates for UATR Accessory

We offer replacement top plates for use with the PerkinElmer Universal ATR accessory.

Research Peltier Accessories : PTP-1, PTP-1+1, PTP-6 and PTP-6+6 accessories

For thermostatting of up to six 1cm cells in the sample beam, stirring possible. Temperature range 0° to 100 °C. Flexible programming of temperature ramps with up to 8 segments is possible. Requires, but does not include, Automatic Linear Transport for LAMBDA 1X/2X/3X/4X/Bio (B2000186) or Linear Cell Programmer for LAMBDA 6XX/8XX/9XX (B2205401). Also requires a water circulator(B0080171) or Peltier Controlled Fluid Circulator (N1015158)

Volatiles Cover for Premium HATR Accessory

This Volatiles Cover is for use with the PerkinElmer Premium HATR Accessory to prevent the evaporation of volatile liquid samples during analysis by HATR.
PerkinElmer

Multiple Reflection HATR

Multiple Reflection HATR with ZnSe Trough and ZnSe Flat Plate includes HATR base optics, ZnSe trough plate, ZnSe flat plate, HATR pressure clamp, HATR powder press, volatiles cover, purge tubes, and spectrometer base mount.
PerkinElmer

Value HATR Trough Top Plate, AMTIR

This Trough Top Plate features an AMTIR (As/Se/Ge) crystal, for use with the PerkinElmer Value HATR accessories.
PerkinElmer

Diffuse Reflectance Accessory for Spectrum One

The Diffuse Reflectance Accessory provides a convenient and sensitive method for analyzing opaque or highly scattering solid samples such as pharmaceuticals, food products, soap powders, coal, clay, soil, paper, painted surfaces, polymer foam and catalysts.
PerkinElmer

Film Polarizer for PerkinElmer Lambda 800/900 Double Polarizer Drive

High-performance film polarizer. One updates the double polarizer drive. For equal energy level in sample and reference beam, two are necessary, Product Number B0505530 and Product Number B0501282. Wavelength range: 400 to 700nm.
PerkinElmer

Peltier Thermostatted Reference Holder for Routine Peltier System

Peltier temperature controlled single cell holder for the reference position. Also included in this product are the power supply, power cables, and User's Guide.
Requires the LAMBDA 25, 35, 45 Accessory Board (L6000500).
PerkinElmer

Value HATR Trough Top Plate, ZnSe

This Trough Top Plate features a Zinc Selenide (ZnSe) crystal, for use with the PerkinElmer Value HATR accessories.
PerkinElmer

Premium HATR Accessory for Spectrum One, ZnSe Trough Top Plate

This Premium HATR Accessory for the Spectrum One allows for superior performance and simple samping of liquids, powders, pastes, and gels.
PerkinElmer

Magnetic Attenuator, 10%

Used to provide additional attenuation when measuring high absorbance materials.

Apex Q system for NexION

Apex Q system for the NexION 300/350. Includes one PFA-100 and PFA-ST nebulizer and adapter to NexION.
PerkinElmer

UATR Accessory for Frontier

The Universal ATR is an excellent general accessory for the analysis of solids and liquids, producing high quality spectra through the use of a pressure arm, allowing for good contact of the sample with the diamond/ZnSe crystal.
PerkinElmer

ATR MIRacle for Spectrum One/100/400/65/Frontier

A single reflection ATR accessory designed for the analysis of highly absorbing solid, semi-liquid and liquid samples. Easily changeable crystal plate design enables analysis of a broad spectrum of sample types while ensuring constant sampling pathlength.

IR Specular Reflection Set

The IR Specular Reflection Set provides a complete solution for state-of-the-art measurement of the emissivity of coated glazing products according to international standards.
PerkinElmer

Powder Press for Premium HATR Accessory

This Powder Press is for use with the PerkinElmer Premium HATR Accessory to allow for the compacting of soft powder samples to prepare for analysis by HATR.

Apex IR system for NexION

Apex IR system for PE NexION. Includes one PFA-100 with manual sampling probe, one PFA-ST nebulizer and adapter to NexION.

"进样系统" 1-50132 产品与服务

每页