PerkinElmer

闪烁液

OF

我们的液体闪烁液方便,易于使用,节省准备时间,并尽量减少实验室误差。我们精心控制的闪烁体混合和质量保证程序以及批次均匀性和批次间的均匀性为每次精确的液体闪烁计数提供最高的性能。

  • 更安全的液体闪烁液,毒性较低
  • 具有最佳性能的传动液体闪烁液
  • 性能,用户安全,环境安全和用户便利性的最高标准
  • 检查每个闪烁混合物的样品接受度,光致发光,化学发光,清晰度,样品容量和计数效率

  • 产品与服务

  • 资源,活动及更多信息

缩小结果
应用
  • LSC (47)
检测方法
  • Radiometric (49)
格式
  • Microplates (7)
  • Filtermat (2)
级别
  • Safer (29)
  • Classical (15)
产品品牌名称
  • Ultima Gold (16)
  • MicroScint (5)
  • Opti-Fluor (3)
  • Flo-Scint (3)
  • Ultima-Flo (3)
  • Biofluor (2)
  • Insta-Gel (2)
  • Pico-Fluor Plus (2)
  • Hionic-Fluor (2)
  • MeltiLex (2)
  • MonoPhase S (2)
  • PermaFluor (2)
  • BetaPlate Scint (1)
  • Insta-Fluor (1)
  • Enlightning (1)
  • SOLVABLE (1)
  • Emulsifier Safe (1)
  • OptiPhase (1)
  • EN3HANCE (1)
  • Filter-Count (1)
  • Carbosorb (1)
样品pH值(0-14)
  • 6-8 (15)
  • < 6 (7)
  • > 8 (6)
样品类型
  • Solid (soluble) (26)
  • Liquid (aqueous) (22)
  • Solid (insoluble) (15)
  • Biological samples (9)
  • Filter (dry) (9)
  • Liquid (organic) (7)
  • Gas (Radon) (7)
  • Gas (CO2) (6)
  • Flow cocktail (5)
  • Filter (wet) (5)
  • Oxidized samples (5)
  • Filter (dissolved) (5)
  • Flow cocktail (water/methanol gradients) (4)
  • Flow cocktail (aqueous gradients) (4)
  • Flow cocktail (ammonium phosphate) (2)
  • Solid (2)
  • Flow cocktail (water/acetonitrile gradients) (2)

"闪烁液" 1-5054 产品与服务

Monophase® S, 2x5L

Sample oxidizer cocktail for tritium counting
PerkinElmer

PICO-FLUOR PLUS / 1 L

Pico-Fluor Plus is a NPE free Liquid Scintillation Cocktail featuring high sample load capacity for aqueous samples and buffer solutions, dompatibility with alkaline tissue solubilizers, compatibility and no background with alkaline sample material, and relatively high Counting efficiency for tritium.
PerkinElmer

Biofluor Plus (1L)

Biofluor® Plus is specially formulated to provide accurate and reproducible high efficiency counting of aqueous samples. It will accept up to 2 mL of a wide variety of aqueous samples in 10 mL cocktail. The continuous single liquid phase formed from zero to the maximum acceptable sample load, avoids unexpected two-phase separation.

Ultima Gold XR, 2x5L

Liquid scintillation cocktail with high sample load capacity.

MicroScint-20, 1L

MicroScint™-20 cocktail was formulated to accept dilute aqueous samples at up to 20% loading. It is the cocktail of choice for counting filters that have not been completely dried.

SOLVABLE, 500mL

SOLVABLE™ is an aqueous based solubilizer that has an excellent capacity for the solubilization of wet tissue, aqueous tissue homogenates, proteins, nucleotides and other substances into a solution. SOLVABLE™ can replace Soluene-350 for many applications, excluding plant material, thus increasing safety in the laboratory due to its aqueous nature.
PerkinElmer

MONOPHASE-S, 1 X 1 LITER

Sample oxidizer cocktail for tritium counting

High Efficiency Mineral Oil Scintillator, 1L

High Efficiency Mineral Oil Scintillator is the cocktail of choice for the detection of radon in water and soil samples.

Opti-Fluor O, 2x5L

Opti-Fluor O is a liquid scintillation cocktail for counting organic samples.

Insta-Gel Plus, 2x5 Liters

Insta-Gel Plus* is the cocktail of choice for a large variety of applications. It excels in the incorporation of water and aqueous-soluble samples, and is equally useful for organic-soluble samples. Simply combine the sample with Insta-Gel Plus, shake to ensure homogeneity and count.

Hionic-Fluor, 1x1 Liters

Hionic-Fluor is a cocktail tailored for samples of high ionic strength and solubilized samples in strong alkaline media. Hionic-Fluor is a pseudocumene-based LSC cocktail, formulated for counting concentrated salt or alkaline solutions, and is recommended for counting concentrated sucrose or cesium chloride gradients.

Ultima-Flo AP, 2x5L

Originally formulated to accept up to 2.0 M ammonium phosphate with fast and easy mixing, Ultima-Flo AP demonstrates high counting efficiency and quench resistance for a wide variety of sample types.

Flo-Scint II

Flo-Scint™ II liquid scintillation cocktail can be used with polar solvents and dilute buffers affording good sample loading capacity and low viscosity

Hionic-Fluor, 2x5 Liters

Hionic-Fluor is a cocktail tailored for samples of high ionic strength and solubilized samples in strong alkaline media. Hionic-Fluor is a pseudocumene-based LSC cocktail, formulated for counting concentrated salt or alkaline solutions, and is recommended for counting concentrated sucrose or cesium chloride gradients.
PerkinElmer

FLO-SCINT A

Flo-Scint™ A is suitable for acetonitrile/water gradients, for counting polar organic solvents and dilute salt solutions. It has excellent sample loading capacities at up to 50% in aqueous solutions. Flo-Scint A is also resistant to chemiluminescence, is non-gelling and has a high counting efficiency.

MicroScint-E, 1L

MicroScint-E cocktail is used for assays that require in situ partitioning of the radionuclide-containing lipid phase from the aqueous phase in microplates.

ULTIMA Gold uLLT, 4x2.5L

Ultima Gold™ uLLT is perfect for ultra low level LSC applications. The ultra low background, high efficiency and good sample uptake is optimal for environmental monitoring applications.

Ultima Gold, 2x5L

Ultima Gold is a safer liquid scintillation cocktail for a wide range of aqueous and nonaqueous samples. Ultima Gold is the ideal, high efficiency, multipurpose LSC cocktail. For samples which exhibit severe quench in conventional cocktails, Ultima Gold provides superior detection efficiency.

MeltiLex, for Microbeta Filters, 14g, 75/PK

MeltiLex®-B solid scintillator for MicroBeta filters. This solid scintillant alternative be melted onto filtermats for scintillation counting.

MicroScint-O, 1L

MicroScint-O cocktail is suitable for counting non-polar organic samples such as hexane, heptane, ethyl acetate etc., and for dried filters.
PerkinElmer

ULTIMA GOLD MV / 1 L

Ultima Gold MV is specifically formulated for the rapid uptake of aqueous and non-aqueous samples. It is recommended for counting wet or damp glass fiber filters from cell harvesters. It is also ideal for counting small volume samples in miniature vials and microtubes because of its reduced viscosity compared to other high flash point cocktails.

ULTIMA Gold uLLT, 1L

Ultima Gold™ uLLT is perfect for ultra low level LSC applications. The ultra low background, high efficiency and good sample uptake is optimal for environmental monitoring applications.

MeltiLex, for Microbeta Filters, 100/PK

MeltiLex®-A solid scintillator for MicroBeta filters. This solid scintillant alternative be melted onto filtermats for scintillation counting.

Insta-Fluor Plus, 4x2.5L

Insta-Fluor Plus is a pseudocumene based LSC cocktail blended for optimal counting of organic samples and nonaqueous solutions. Simply combine the organic sample with Insta-Fluor Plus, shake to ensure homogeneity and count. Insta-Fluor Plus is ideally suited for use in two-phase extraction assays (e.g. CAT assays).
PerkinElmer

Permafluor® E+, 4x2.5L

Permafluor® E+ is a pseudocumene-based cocktail specifically formulated for use in Packard's Model 307 Sample Oxidizer system. This cocktail is designed for counting 14CO2 samples that are trapped in Carbo-Sorb® E.

MicroScintPS, 1L

MicroScint™-PS cocktail was specifically formulated for polystyrene compatibility. It is suitable for use with virtually any type of microplate and provides long term counting stability.

Ultima Gold, 5L

Ultima Gold™ is a safer liquid scintillation cocktail for a wide range of aqueous and nonaqueous samples. Ultima Gold™ is the ideal, high efficiency, multipurpose LSC cocktail. For samples which exhibit severe quench in conventional cocktails, Ultima Gold™ provides superior detection efficiency.

Ultima Gold LLT, 1L

Liquid scintillation cocktail allows you to determine low levels of 3H in a wide range of water samples without requiring distillation.

Ultima Gold MV, 2x5L

Ultima Gold MV is specifically formulated for the rapid uptake of aqueous and non-aqueous samples. It is recommended for counting wet or damp glass fiber filters from cell harvesters. It is also ideal for counting small volume samples in miniature vials and microtubes because of its reduced viscosity compared to other high flash point cocktails.
PerkinElmer

Betaplate Scint for Betaplate, 5L

Betaplate Scint is a HiSafe cocktail for samples harvested or spotted onto dry filter membranes. High counting efficiency may eliminate sample pre-treatment often necessary with conventional cocktails. Ideal for use with samples in organic solutions.

Ultima Gold F, 2x5L

Ultima Gold™ F is a high efficiency, safer liquid scintillation cocktail for counting dry filter supports, as well as organic samples. For alpha/beta LSC counting, Ultima Gold™ F is an ideal diluent for Ultima Gold™ AB, increasing energy resolutions and pulse-shape discrimination for small volume samples.
PerkinElmer

Optiphase HiSafe 3, 5L

Our OptiPhase HiSafe family of safer LSC cocktails uses the solvent di-isopropylnaphthalene (DIN) to achieve improved safety without decreasing performance.
PerkinElmer

ENHANCE 1 X 1 LITER

EN3HANCE™ is a liquid autoradiography enhancer that greatly simplifies gel processing as compared to Bonner and Lasky's method.

Ultima Gold AB, 2x5L

Ultima Gold™ AB is the world's first liquid scintillation cocktail specifically designed for alpha/beta discrimination in liquid scintillation counting (LSC).

Emulsifier-Safe, 2x5L

Emulsifier-Safe™, based on a high flash-point solvent (LAB), is an economically priced LSC cocktail for aqueous and organic samples. Aqueous samples and many buffer solutions are accepted in a single liquid phase up to 10-15% maximum sample load.
PerkinElmer

Permafluor® E+, 1x1L

Permafluor® E+ is a pseudocumene-based cocktail specifically formulated for use in Packard's Model 307 Sample Oxidizer system. This cocktail is designed for counting 14CO2 samples that are trapped in Carbo-Sorb® E.

Filter Count, 1 Liter

Liquid scintillation cocktail for dissolving filters for liquid scintillation counting (LSC).
PerkinElmer

PICO-FLUOR PLUS / 2*5 L

Pico-Fluor Plus is a NPE free Liquid Scintillation Cocktail featuring high sample load capacity for aqueous samples and buffer solutions, dompatibility with alkaline tissue solubilizers, compatibility and no background with alkaline sample material, and relatively high Counting efficiency for tritium.

Flo-Scint III

Flo-Scint™ III is designed to work with methanol and acetonitrile gradients as well as moderately buffered solutions, including phosphates. It has good sample loading capacity, low viscosity and high counting efficiency.

Ultima Gold XR, 4x2.5L

Ultima Gold™ XR is a safer liquid scintillation cocktail with a very high sample load capacity. Ultima Gold XR is the right choice when large sample volumes need to be counted or when miniature vials are required for higher throughput. This results in a reduced cost per sample and helps keep radioactive waste to a minimum. Ultima Gold™ XR is compatible with alkaline samples.

Opti-Fluor O, 1L

Opti-Fluor O is a liquid scintillation cocktail for counting organic samples.

Carbo-Sorb® E, 1L

Carbo-Sorb® E is a high capacity radioactive dioxide absorber compatible with the counting cocktail Permafluor E+.

MicroScint 40, 1L

MicroScint™-40 cocktail was primarily developed to accept dilute aqueous samples at up to 40% loading, but was also found to be suitable for more concentrated samples. MicroScint™-40 cocktail also mixes easily with most sample types but slightly longer agitation may be necessary when handling large sample volumes. It has an absolute, unquenched Tritium efficiency of approximately 40% when measured in a 24-well white polystyrene OptiPlate microplate.

Ultima Gold AB, 1x1L

Ultima Gold™ AB is the world's first liquid scintillation cocktail specifically designed for alpha/beta discrimination in liquid scintillation counting (LSC).

Ultima-Flo AP, 1L

Originally formulated to accept up to 2.0 M ammonium phosphate with fast and easy mixing, Ultima-Flo AP demonstrates high counting efficiency and quench resistance for a wide variety of sample types.

Opti-Fluor, 2x5L

Opti-Fluor is a universal, safer liquid scintillation cocktail based on the high flash-point solvent LAB (Linear Alkylbenzene). Opti-Fluor does not show any diffusion through the walls of polyethylene vials as is observed with many LSC cocktails containing toluene, xylene or pseudocumene.

Ultima Gold LLT, 4x2.5L

Liquid scintillation cocktail allows you to determine low levels of 3H in a wide range of water samples without requiring distillation.

Ultima-Flo M, 2x5L

Formulated for multipurpose flow counting applications, this safer cocktail has a high sample acceptance for a wide range of HPLC gradients. Ultima-Flo M has low viscosity, unique rapid mixing properties and is resistant to chemiluminescence.
PerkinElmer

Ultima Gold, 4x2.5L

Ultima Gold™ is a safer liquid scintillation cocktail for a wide range of aqueous and nonaqueous samples. Ultima Gold™ is the ideal, high efficiency, multipurpose LSC cocktail. For samples which exhibit severe quench in conventional cocktails, Ultima Gold™ provides superior detection efficiency.

"闪烁液" 1-5054 产品与服务