PerkinElmer

热脱附仪

OF

自动热解吸技术可以简化和加快您的样品制备,被广泛应用于室内和室外空气监测,半导体材料、聚合物、室内装潢和家具的释放气体检测。

我们的热脱附仪是各种气相色谱仪(GC)应用的理想选择,包括从各种材料中分离出气体,分析香精和香料等。<

  • 产品与服务

  • 资源,活动及更多信息

缩小结果
产品类型
  • Consumables (89)
  • Accessories (19)
长度
  • 51-100 (3)
材料
  • Stainless Steel (27)
  • Glass (19)
  • PTFE (7)
  • KALREZ (2)
  • Graphite/Vespel (2)
  • Brass (1)
  • Viton (1)
  • Graphite (1)
温度-最高
  • 30-40 (5)
温度-最低
  • 10-20 (5)
产品品牌名称
  • TurboMatrix (5)

"热脱附仪" 1-50108 产品与服务

每页
PerkinElmer
PerkinElmer

TurboMatrix Thermal Desorber Trap, Packed with Tenax

The TurboMatrix air monitoring trap is packed with carbonaceous sorbents suitable for ozone precursor and air toxics monitoring..
PerkinElmer

TurboMatrix Analytical Caps PTFE Caps with O-Ring, Cold Traps Fittings and Accessories (20/pack)

Required for use on the TurboMatrix instrument during analysis (use with brass long-term storage caps).
PerkinElmer

Brass Storage End Caps and Ferrule Set Kit For TD Tubes

Kit contains 20pcs each of Brass caps and PTFE ferrules for long-term storage of Thermal Desorber Tubes.

TurboMatrix Thermal Desorber Starter Kit

The starter kit is recommended for all purchasers who do not already have a TurboMatrix Thermal Desorber.
PerkinElmer

TurboMatrix Thermal Desorber Trap, Empty

TurboMatrix Thermal Desorption Trap Supplies Trap supplies from PerkinElmer, the market leader in thermal desorption, willprovide exceptional analytical performance. Used for U.S. EPA Method TO17, thePerkinElmer standard trap, packed with Tenax, on the TurboMatrix ThermalDesorber, will improve productivity and trapping capacity.
PerkinElmer

Options Board/BCD Output Board

Required for installation of the following options on an entry-level thermal desorber - Internal Standard Addition, On-line Sampling, or Liquid Nitrogen Cooling. Also provides output of BCD information regarding tube position numbers and provides relay output for timed control of external devices.
PerkinElmer

Diffusion Caps with Membrane, Pkg 10

For passive air sampling to ensure correct diffusion path length. Same as standard diffusion caps but with a silicone membrane.

Stainless Steel ATD Prepacked Sample Tubes, Sorbent: Air Toxics Tube, Pkg 10

The Air Toxics tube is conditioned at 350 °C. PerkinElmer recommends a maximum temperature of 400 °C for this sample tube with a desorption temperature of 330 °C. The tubes approximate analyte volatility range is n-C3 to n-C12 and the typical analytes for he Air Toxics are EPA TO-14 compounds.
PerkinElmer

Cold Trap Nut for ATD, Pkg 1

Two required per trap tube.

Stainless Steel Prepacked ATD Sample Tubes, Sorbent: Carbopack™ B 60/80, Carbopack™ C 60/80 Carbosieve™ Slll 60/80, Pkg 10

This tube is a multifunctional combination tube which allows detection of 3 compounds. The SS tubes are compatible with pumped and diffusive air monitoring. Suitable for direct sampling of solids and liquids. PerkinElmer tubes are manufactured to the tightest spcifications to ensure trouble free operation and high quality analysis results.
PerkinElmer

PTFE Ferrule, Pkg 10

Ferrules for cold trap. Recommended for use with Mass Spec or ECD.
PerkinElmer

ATD Cold Trap Tube, Unpacked, Pkg 1

Standard cold trap tube unpacked.

Cold Trap Tube, Low Flow, Unpacked for ATD 400, Pkg 1

Cold trap with reduced bore at one end. Allows minimum gas flow
during trap desorption.

"热脱附仪" 1-50108 产品与服务

每页