PerkinElmer

热脱附仪

OF

自动热解吸技术可以简化和加快您的样品制备,被广泛应用于室内和室外空气监测,半导体材料、聚合物、室内装潢和家具的释放气体检测。

我们的热脱附仪是各种气相色谱仪(GC)应用的理想选择,包括从各种材料中分离出气体,分析香精和香料等。<

  • 产品与服务

  • 资源,活动及更多信息

缩小结果
产品类型
  • Consumables (89)
  • Accessories (19)
长度
  • 51-100 (3)
材料
  • Stainless Steel (27)
  • Glass (19)
  • PTFE (7)
  • KALREZ (2)
  • Graphite/Vespel (2)
  • Brass (1)
  • Viton (1)
  • Graphite (1)
温度-最高
  • 30-40 (5)
温度-最低
  • 10-20 (5)
产品品牌名称
  • TurboMatrix (5)

"热脱附仪" 1-50108 产品与服务

每页
PerkinElmer

Standard Diffusion Caps, Pkg 10

For passive air sampling to ensure correct diffusion path length.

Stainless Steel Prepacked ATD Sample Tubes, Sorbent: Carbopack™ B 60/80, Carbopack™ C 60/80 Carbosieve™ Slll 60/80, Pkg 10

This tube is a multifunctional combination tube which allows detection of 3 compounds. The SS tubes are compatible with pumped and diffusive air monitoring. Suitable for direct sampling of solids and liquids. PerkinElmer tubes are manufactured to the tightest spcifications to ensure trouble free operation and high quality analysis results.
PerkinElmer

PTFE Ferrule, Pkg 10

Ferrules for cold trap. Recommended for use with Mass Spec or ECD.
PerkinElmer

Stainless Steel empty ATD Sample Tubes Without Caps, Pkg 100

These are unconditioned thermal desorber tubes that are empty and without caps. Stainless component.

Stainless Steel Prepacked ATD Sample Tubes , Sorbent: Carbotrap 349 (NIOSH 2549) Tube

The Carbotrap 349 is conditional at 350 °C. The recommended temperature is a maximum temperature of 400 °C for this sample tube with a desorption temperature of 330 °C. The tubes approximate analyte volatility range is n-C3 to n-C16 and the typical analytes for the Carbotrap 349 are NIOSH Method 2549.
PerkinElmer

TurboMatrix Thermal Desorber Trap, Packed with Tenax

The TurboMatrix air monitoring trap is packed with carbonaceous sorbents suitable for ozone precursor and air toxics monitoring..

Cold Trap Tube, Low Flow, Unpacked for ATD 400, Pkg 1

Cold trap with reduced bore at one end. Allows minimum gas flow
during trap desorption.
PerkinElmer

Graphite Ferrule, Pkg 2

Ferrule for cold trap. Recommended for all applications except those using Mass Spec or ECD (Use P/N L4275110 PTFE Ferrule).

Stainless Steel ATD Prepacked Sample Tubes, Sorbent: Tenax™ TA60/80 Pkg 10

All your consumable needs in one convenient kit, designed specifically for Industrial Hygiene using Thermal Desorption.

Stainless Steel Prepacked ATD Tubes, Sorbent: Carbotrap C/B, Pkg 10

Stainless Steel packed thermal desorber tubes. Packing material: Carbotrap C 20/40 and Carbotrap B 20/40. Fully conditioned with brass long-term storage caps PK/10
PerkinElmer

Options Board/BCD Output Board

Required for installation of the following options on an entry-level thermal desorber - Internal Standard Addition, On-line Sampling, or Liquid Nitrogen Cooling. Also provides output of BCD information regarding tube position numbers and provides relay output for timed control of external devices.
PerkinElmer

TurboMatrix Air Monitoring Trap

Trap packed with carboneous sorbents suitable for ozone precursor and air toxics monitoring.

Stainless Steel ATD Prepacked Sample Tubes, Sorbent: Carbopack™ B 60/80, Pkg 10

The Carbopack™ B is conditioned at 350 °C. PerkinElmer recommends a maximum temperature of 400 °C for this sample tube with a desorption temperature of 330 °C. The tubes approximate analyte volatility range is n-C5 to n-C12 and the typical analytes for the Carbopack™ B are a wide range of VOCs.
PerkinElmer

Cold Trap Nut for ATD, Pkg 1

Two required per trap tube.
PerkinElmer

ATD Cold Trap Tube, Unpacked, Pkg 1

Standard cold trap tube unpacked.
PerkinElmer

TurboMatrix Analytical Caps PTFE Caps with O-Ring, Cold Traps Fittings and Accessories (20/pack)

Required for use on the TurboMatrix instrument during analysis (use with brass long-term storage caps).

"热脱附仪" 1-50108 产品与服务

每页