TSA Plus Cyanine 5.5, 50-150 Slides

TSA® Plus Cyanine 5.5 (Cy5.5) detection kit, for amplification of signal in immunohistochemistry (IHC), immunofluorescence (IF) or in situ hybridization protocols. This kit amplifies by depositing extra Cy5.5 in the localized area of the probe or antibody.

项目已成功添加到购物车

部件号
产品尺寸
NEL766E001KT
1 Kit
更多
NEL766001KT
50-150 slides
更多
NEL766B001KT
250-750 slides
更多
立即购买

请输入有效的数量

请登录后再添加至收藏夹

购物车为空

详情 信息

TSA Plus kits deliver ultimate sensitivity in immunohistochemistry (IHC), immunofluorescence (IF), and in situ hybridization (ISH) assays. This widely referenced method uses horseradish peroxidase (HRP) to mediate intense covalent deposition of detection labels at very close proximity to the epitope or sequence of interest. TSA Plus has been employed for quantitative detection in a wide variety of sample types including formalin-fixed, paraffin-embedded (FFPE) tissue, cryosections and cultured cells.

TSA Plus Cyanine 5.5 provides another option for fluorescent detection with spectral characteristics that are generally similar to Alexa Fluor 680® or IRDye® 680LT. It has maximum absorbance at 673 nm and maximum emission at 692 nm.

TSA Plus Cyanine 5.5 is ideal for multiplexed IHC or ISH in combination with other TSA fluorophores. The Opal™ protocol allows simultaneous measurement of 6 or more biomarkers in FFPE tissue.

规格

荧光基团 Cy5.5
产品品牌名称 TSA Plus
运输条件 蓝冰
产品尺寸 50-150 slides
资源,活动及更多信息
  • 所有

产品手册

TSA™ Signal Amplification for IHC, ICC, IF

The extraordinary sensitivity of the Tyramide Signal Amplification (TSA™) kits from PerkinElmer lets you see previously undetectable levels of protein and nucleic acid. The resolution is remarkable. And with multi-target detection, you can get more information from each experiment. It’s clear to see. TSA makes it easy to gain valuable insight from your immunohistochemistry (IHC) and immunocytochemistry (ICC) results.

PDF 3 MB
TSA™ Signal Amplification for ISH

Tyramide Signal Amplification (TSA™) provides remarkable sensitivity enhancement for your ISH experiments without the drawbacks associated with other methods. Signal amplification with TSA allows detection at levels as low as asingle copy and enables the use of shorter probes for more precise localization of targets. The TSA reaction occurs within 10 minutes, and labels are bonded covalently, ensuring outstanding resolution.

PDF 2 MB

单页

Opal Multiplex Tissue Staining Flyer

Opal™ is a practical workflow for specific staining of multiple tissue biomarkers able to reach to 8-plex and beyond in a single image.

PDF 2 MB

操作手册