PerkinElmer

样品制备消耗品和用品

OF

为了避免因样品制备中发生错误造成对后续分析阶段的数据质量造成损害。样品制备通常占用了您60%的实验时间,它对实验室产能和分析性能有着决定性的影响。

在PerkinElmer,我们为您提供了成功实验所需的一系列样品制备消耗品和用品,包括微波消解系统的消耗品,样品制备块(SPB)和固相萃取柱(SPE)

  • 产品与服务

  • 资源,活动及更多信息

缩小结果
产品类型
  • Consumables (425)
  • Accessories (1)
应用
  • Mass Spectrometry (3)
颜色
  • Purple (4)
  • Clear (2)
  • Yellow (2)
型号兼容
  • Solid Phase Extraction (SPE) (242)
  • Sample Preparation Blocks (62)
  • Titan Microwave System (55)
  • Quechers Dispersive SPE (19)
  • Titan (1)
  • FT-IR Sampling Kit (1)
  • NexION 2000 (1)
  • NexION 1000 (1)
外径
  • 35 mm (1)
产品品牌名称
  • Custodion® (2)
  • Titan (1)
  • Torion® (1)
产品组
  • Columns (168)
  • Syringe Filters (32)
  • Well plates (32)
  • Vessels and Spares (23)
  • DigestionTubes (16)
  • Clean-up Kits (16)
  • Column Application Packs (14)
  • Racks (13)
  • Probes and Holders (12)
  • Titan Replacement Parts (10)
  • Start Up Kits (8)
  • Turntables (7)
  • Column Selection Kits (7)
  • Screw Caps (7)
  • Cartridges (6)
  • Lip Forming Seals (5)
  • Disposable Syringes (4)
  • Watch Glasses (4)
  • Needles (4)
  • Extraction Kits (3)
  • Titan Accessories (3)
  • Gas Containment Manifold (3)
  • DigiFILTERs (3)
  • Weighing Cups (2)
  • Vacuum Manifolds (2)
  • Replacement Chambers (2)
  • Consumable Run Kits (2)
  • Cover Gasket (2)
  • Vacuum Pump (2)
  • Stopcocks (2)
  • Drying Attachment (2)
  • Organic (1)
  • Pestle and Mortars (1)
标准型
  • Powder (1)
技术类型
  • ICP-MS (1)
  • FT-IR (1)
  • ICP-OES (1)
  • ICP-OES, ICP-MS, AA (1)
体积容量
  • 3 mL (67)
  • 6 mL (61)
  • 15 mL (41)
  • 2 mL (39)
  • 1 mL (37)
  • 50 mL (29)
  • 100 mL (17)
  • 0.22 µm (16)
  • 0.45 µm (16)
  • 25 mL (6)
  • 62.5 mL (3)
  • 10 mL (1)
  • 5 mL (1)
  • 75 mL (1)

"样品制备消耗品和用品" 1-50426 产品与服务

每页

DPC Glass prism for Standard 75 mL (40 Bar) and 100 mL (100 Bar) Digestion Vessels

Glass prism for Digestion Vessel caps with pressure control (DPC) for Standard 75 mL (40 Bar) Digestion Vessel and High Pressure 100 mL (100 Bar) Digestion Vessel for Microwave Titan MPS Sample Preparation Systems.

Orange PTFE (Hydrophobic) Syringe Filters, 0.45 µm, 30 mm (100/pack)

Hydrophobic PTFE syringe filters have broad chemical compatibility and high pH resistance. These are versatile filters for use with aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation.

PTFE Screw Cap for PTFE 50 mL, qty. 6

PerkinElmer offers different color DigiTube Cap options depending on your laboratory requirements.

Eight-Seal Lip Forming Tool for Standard 75 mL (40 Bar) Digestion Vessel Pressure Seals

Forming tool for pressure seals used with Standard 75 mL (40 Bar) Digestion Vessels. Forms up to 8 seals simultaneously.

Purple Nylon Syringe Filters, 0.22 μm

Hydrophilic Nylon is ideal for aqueous (non-acidic) or organic sample prep and HPLC, GC or dissolution sample analysis. With its excellent flow characteristics, very low extractable levels and mechanical stability, Nylon offers the best combination of physical parameters to meet the most stringent analytical needs. The naturally hydrophilic, high protein binding and high dirt loading capacity of Nylon are natural advantages.
PerkinElmer

SPE Supra-Poly® XC (Extreme Capacity 1500 m2/g) Column, 1 g/15 mL, Pack of 20

Extreme Capacity (XC) polystyrene-divinylbenzene Supra-Poly Spherical Polymer-based Solid Phase Extraction (SPE) products are recommended for extracting polar and non-polar compounds when analyzing drugs and drug metabolites biological fluids.

10 mL BD Luer-Lok™ Disposable Syringe PK/100

Designed for use with syringe filters. These disposable, sterile, polypropylene syringes are for general-purpose applications. Packaged in easy-to-open sealed package and they can be autoclaved out of the package.
PerkinElmer

SPE Supra-Clean® C18-S Column, 50 mg/1 mL, Pack of 50

C18-S Supra-Clean® Spherical Silica-based Solid Phase Extraction (SPE) Columns are recommended for extracting mid-polar to non-polar compounds when analyzing drugs and drug metabolites in biological matrices, trace organic material in water, and toxins in food. SPE Format: Straight PP TubeMedia Weight: 50 mgFormat Capacity: 1 mLQuantity: 50

Yellow PVDF Syringe Filters, 0.22 µm, 13 mm (100/pack)

PVDF (Hydrophobic Polyvinylidene Fluoride) syringe filters are ideal for a wide range of mild organic solutions. PVDF membranes are not recommended for use with acetone, DMF, DMSO, or bases >6N.

Supra-Poly SPE HLB (Hydrophilic/Lipophilic Balanced) Column, 60 µm, 500 mg/3 mL

Supra-Poly Hydrophilic/Lipophilic Balanced HLB SPE Columns are designed to extract mid-polar and non-polar compounds in aqueous and organic solvents. 
PerkinElmer

SPE Supra-Clean® C18 Column, 500 mg/3 mL, Not end-capped

Supra-Clean SPE products are available in a range of media weights, volumes and formats, including easy to order selection its and application packs.

  • Pure spherical silica
  • Pore size 60 – 120 Å
  • 17 chemistries with pH range 2 – 8.

 

PerkinElmer

SPE Supra-Clean® FL-S (Florisil Pesticides Grade, Granular Shape) Column, 2 g/6 mL, Pack of 30

Florisil Pesticide (FL-S) Supra-Clean Silica-based Solid Phase Extraction (SPE) products are recommended for extracting polar compounds when analyzing pesticides. SPE Format: Straight PP TubeMedia Weight: 2 gFormat Capacity: 6 mLQuantity: 30

Rack for SPB 100-30 100 mL

For busy labs, additional acid resistant, polycarbonate Racks are available for all SPB systems. Exclusive RackLock feature locksDigiTUBE®s in position within the rack allowing for easy, one-handed closure of screw cap.

High Pressure 100 mL (100 Bar) Digestion Vessel Base (Base Only)

Vessel base made of TFM for High Pressure 100 mL (100 Bar) Digestion Vessel for Titan MPS™ 8 Position Microwave Sample Preparation Systems.

Aluminum Oxide Powder, 28g.

Operating Tip: Place some aluminum oxide powder between the sampling and the cup to prevent the sample from adhering to the cup.

Supra-Poly SPE HLB (Hydrophilic/Lipophilic Balanced) Column, 60 µm, 500 mg/6 mL

Supra-Poly Hydrophilic/Lipophilic Balanced HLB SPE Columns are designed to extract mid-polar and non-polar compounds in aqueous and organic solvents. 

Fruit & Vegetables AOAC 2007.01 Clean-up Kit, 2 mL

QuEChERS AOAC 2007.01 Clean-up Kit for Fruit & Vegetables are conveniently packed in ready-to-use tubes for clean-up of fruits and vegetables. 

Nylon Syringe Filters, 0.45 μm

Ideal for aqueous (non-acidic) or organic sample preparation and HPLC, GC or dissolution sample analysis. With its excellent flow characteristics, very low extractable levels and mechanical stability, Nylon offers the best combination of physical parameters to meet the most stringent analytical needs.

Supra-Poly SPE HLB (Hydrophilic/Lipophilic Balanced) Column, 30 µm, 30 mg/15 mL

Supra-Poly Hydrophilic/Lipophilic Balanced HLB SPE Columns are designed to extract mid-polar and non-polar compounds in aqueous and organic solvents. 
PerkinElmer

SPE Supra-Clean® Phenyl (PH-S) 96 Well Plate, 50 mg/2 mL

Phenyl (PH-S) Supra-Clean® Spherical Silica-based Solid Phase Extraction (SPE) products are recommended for extracting non-polar to mid-polar aromatic compounds when analyzing Benzodiazepines

Liner F100 PTFE-TFM

Reaction vessel made of PTFE-TFM (tetrafluoroethylene, modified). Optionally used as liner in pressure vessels MF100 and HF100 for longer life with high temperature applications.
PerkinElmer

SPE Supra-Poly® XWP (Extra Wide Particle 1200 m2/g) Column, 100 mg/3 mL, Pack of 50

Extreme Capacity Wide Pore (XWP) polystyrene-divinylbenzene Supra-Poly Spherical Polymer-based Solid Phase Extraction (SPE) products are recommended for extracting polar and non-polar compounds when analyzing drugs and drug metabolites biological fluids.

Supra-Poly SPE HLB (Hydrophilic/Lipophilic Balanced) Column, 30 µm, 100 mg/6 mL

Supra-Poly Hydrophilic/Lipophilic Balanced HLB SPE Columns are designed to extract mid-polar and non-polar compounds in aqueous and organic solvents. 
PerkinElmer

SPE Supra-Poly® XC (Extreme Capacity 1500 m2/g) Column, 30 mg/1 mL, Pack of 50

Extreme Capacity (XC) polystyrene-divinylbenzene Supra-Poly Spherical Polymer-based Solid Phase Extraction (SPE) products are recommended for extracting polar and non-polar compounds when analyzing drugs and drug metabolites biological fluids.
SPE Format: Straight PP Tube
Media Weight: 30 mg
Format Capacity: 1 mL
Quantity: 50
PerkinElmer

SPE Supra-Clean® WCX (Weak Cation Exchange) Column, 500 mg/3 mL, Pack of 50

Weak Cation Exchange (WCX) Supra-Clean Spherical Silica-based Solid Phase Extraction (SPE) columns are recommended for extracting strong basic compounds when analyzing cations, amines, antibiotics, drugs, amino acids, catecholamines, nucleic acid bases, nucleosides, and surfactants. SPE Format: Straight PP TubeMedia Weight: 500 mgFormat Capacity: 3 mLQuantity: 50

Clear PTFE (Hydrophobic) Syringe Filters, 0.22 µm, 4 mm (200/Pack)

Clear PTFE (Hydrophobic) Syringe Filters, 0.22 μm, 4 mm (200/Pack) have broad chemical compatibility and high pH resistance. These are versatile filters for use with aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation. The pure polypropylene housings are color-coded and available in smooth rim or gear rim formats.
PerkinElmer

SPE Supra-Poly® XWP (Extra Wide Particle 1200 m2/g) Column, 60 mg/3 mL, Pack of 50

Extreme Capacity Wide Pore (XWP) polystyrene-divinylbenzene Supra-Poly Spherical Polymer-based Solid Phase Extraction (SPE) products are recommended for extracting polar and non-polar compounds when analyzing drugs and drug metabolites biological fluids. SPE Format: Straight PP TubeMedia Weight: 60 mgFormat Capacity: 3 mLQuantity: 50
PerkinElmer

SPE Supra-Clean® 300Å C4 Column, 100 mg/1 mL, Pack of 100

SPE Supra-Clean 300Å (C4) Columns for extracting non-polar to mid-polar compounds which require large pore size media. 

Seal for Pressure Vessel M & H

Lip type seal made of PTFE-TFM with venting system. Fits both pressure vessels of the Rotor 16, vessel MF100 and HF100.

"样品制备消耗品和用品" 1-50426 产品与服务

每页