PerkinElmer

热分析

OF

使用我们全面的热分析仪器系列,提高热分析的精确度,灵敏度和性能。我们业界领先技术的应用包括:

  • QA/QC应用
  • 药物过程研究
  • 聚合物研究
  • 回收塑料的识别
  • 包装材料的测定
  • 纳米材料
  • 涂料
  • 复合材料
  • 其他更多

仅供科学研究,非临床诊断用途。

  • 产品与服务

  • 资源,活动及更多信息

缩小结果
产品类型
  • Consumables (92)
  • Accessories (84)
  • Instruments (10)
  • Software and Informatics (1)
  • Service Parts (1)
自动化兼容
  • Yes (1)
材料
  • Aluminum (28)
  • Platinum (10)
  • Stainless Steel (6)
  • Alumina (4)
  • Ceramic (4)
  • Nichrome (4)
  • Quartz (3)
  • Copper (2)
  • Titanium (2)
  • Tygon (1)
  • Gold (1)
  • Graphite (1)
  • Gold-plated (1)
温度-最高
  • Over 100 (10)
温度-最低
  • 10-20 (2)
型号兼容
  • DMA 8000 (11)
  • Diamond TMA (6)
  • Diamond DMA (2)
  • FT-IR (1)
  • TGA (1)
产品组
  • Sample Pans (45)
  • Pan Crimper (15)
  • Probes and Sample Tools (9)
  • Starter Kit (7)
  • Liners (4)
  • Covers (4)
  • Sample Cups (3)
  • Spares Kits (3)
  • Plates and Replacement Parts (3)
  • Humidity Sensor (3)
  • Material Pockets (3)
  • Forceps (2)
  • PMMA (2)
  • Mesh Pockets (2)
  • Clamp Assemblies and Replacement Parts (2)
  • Bending Replacement Parts (2)
  • Sample Stages (2)
  • Cylinders (2)
  • Measuring Systems (1)
  • Gas Purge (1)
  • Dilatometer Cells (1)
  • Probe Assembly (1)
  • Crucible Kit (1)
  • Flow Meter (1)
  • Gas Station (1)
  • Microswitch Extension (1)
  • Air Dryer (1)
  • Sample Tubes (1)
  • Replacement Parts (1)
  • Cups (1)
  • Regulator (1)
  • Stirrup Kit (1)
  • Adapter Kits (1)
  • Sample Loading Tool (1)
  • Sample Load Fixture (1)
  • Sample Holder (1)
  • Capsule Kit (1)
  • Book (1)
  • UV Lamps (1)
  • Sample Holder Cover Reforming Tool (1)
  • DMA Assembly (1)
技术
  • Thermal Analysis (8)
技术类型
  • EA (23)
  • DSC (12)
  • Thermal Analysis (9)
  • CHNO (2)
  • Tubing Spares (1)
  • TGA (1)
体积容量
  • 40 µL (7)
  • 30 µL (6)
  • 60 µL (4)
  • 50 µL (3)
  • 12.5 µL (2)
  • 20 µL (2)
  • 10 µL (2)

"热分析" 1-50188 产品与服务

每页

DSC 4000 系统, 100-240V/50-60Hz

DSC4000型差示扫描量热仪采用单炉体设计,结构紧凑,性能十分优异。应用范围广泛,覆盖了从日常教学科研、新材料表征药物研发以及市场常规检测等诸多领域。可提供可靠的性能、优异的数据重现性以及简便的操作方法。此外,其包覆式热电偶设计可耐受氧气和化学物质的侵蚀,服役寿命长。

LAB SYS-DSC 8500

DSC8500拥有第二代HyperDSC技术、双炉体设计和更佳的测试能力,其准确度和灵敏度胜过目前任何一款DSC。
DMA 8000 N5330101

DMA 8000 SYS QUARTZ WINDOW SS/Ti CLAMPS

DMA 8000的创新型设计、高效灵活的操作使之成为材料研究开发和生产线质量控制的理想仪器。可广泛应用于聚合物、复合材料、制药以及食品行业。

同步热分析仪 (STA) 6000

The STA 6000 同步热分析仪可提供您可以依赖的性能,可靠性和生产力。
TMA4000_Silhouette_wNameplate_320px

TMA 4000 实验室系统, 100-230V

PerkinElmer公司的TMA 4000是一款设计简洁、使用方便、稳固耐用的热机械分析仪,非常适合于精确测量微型元器件/材料的膨胀系数(CTE)等应用领域。

DSC 6000

DSC6000型差示扫描量热分析仪采用单炉体设计,除了具备DSC4000型仪器的所有性能优势以外,还可提供给您更多的特性设计。标配的温度调制技术(MT-DSC)简化了数据分析过程,适用于新产品的研发以及疑难问题解决等应用领域。
Simultaneous Thermal Analyzer (STA) 8000

同步热分析仪 (STA) 8000

STA 8000同步热分析仪可提供您可以依赖的性能,可靠性和生产力。
TGA 4000 N5370210

TGA 4000 系统, 100-240V/50-60Hz

TGA 4000 炉体采用集约式陶瓷设计,温度控制准确度和精度更高。其陶瓷炉体耐化学腐蚀性优异,适用于多种活性气体气氛,可充分拓展您的研究领域。

DSC 8000

DSC 8000特有的双炉体技术,直接测量两个独立炉体之间热流变化,可在全程温度范围得到非常准确的能量数据,从而满足您在科研方面的高级需求。

TGA 8000

PerkinElmer公司全新推出的TGA8000™型热重分析仪不仅可以让您完全掌控样品的测试环境,而且兼顾了测试所需的高通量和数据可靠性,甚至在无人值守的状态下依然可以完美的高效运行。另外,PerkinElmer公司先进的联用技术赋予这款仪器完美的与FTIR,MS,GC/MS进行联合使用,让您能够透彻的研究逸出气体的定性定量信息。

Vented Platinum Sample Holder Covers, Pkg.2

Each cover has two vent holes and is used for the Pyris 1 DSC, DSC 7, DSC-4, and DSC-2 sample holders.
PerkinElmer

Alumina Sample Cups, 60mm3, Pkg.6

Use alumina cups if the sample is to be brought to temperatures higher than 1500°C and when metal samples are being run.
PerkinElmer

Volatile Sealer Assembly

For use with volatile, viscous,noncorrosive samples.

Vented Platinum Sample Holder Covers, Pkg.6

Each cover has two vent holes and is used for the Pyris 1 DSC, DSC 7, DSC-4, and DSC-2 sample holders.

Auto sampler Aluminum Sample Pans (covers not included), 50µL, 0.1mm, Sealed, Pkg.400

Pans contain the sample in a sealed environment throughout an experiment. The sealing suppresses the vaporization of a solvent or contains a volatile reaction product, thereby eliminating the interfering effects of the heat of vaporization.

Copper Sample Pans and Covers, Pkg.200

Can be used for samples that have transitions that occur above the temperature range of the AI pans. Typical applications include antioxidant testing, thermoset and thermoplastic glass transition and melting point determinations. Not for use with Diamond DSC,PYRIS 1 DSC, or DSC Autosampler.

Stainless Steel Pans, Covers and O-Rings, Pkg.20

Under no circumstances should the capsules be heated above 300° C. Any application requiring the heating beyond 200° C or where gaseous decomposition products may be generated should first be tested outside of the instrument. Always use guard ring inserts in conjunction with the sealed capsules. Included in the Large Volume Stainless Steel Capsule Kit (P/N 03190021).
PerkinElmer

Aluminum Pan Starter Kit for the Pyris 1 Autosampler, DSC 7 RS and DSC-4 RS. Includes 50 of each type of aluminum pan and 350 covers

The Autosampler sample pans are used to prepare sample materials for your DSC Autosampler. Pans are available in sealed or vented versions. These pans may also be used for non-robotic systems.
PerkinElmer

Solid Aluminum Covers (400/pack)

These covers are for 3 bars maximum pressure. The temperature range is from -170° to 600 °C. Requires crimper B0139005.

HyperDSC™ Aluminum Sample Pans, Package of 100

Ultra-light sample pans. Package of 100, Ø 6mm X 3.75mm height. Do not require a sealing tool.
PerkinElmer

Alumina Sample Cups, 60mm3, Pkg.25

Use alumina cups if the sample is to be brought to temperatures higher than 1500°C and when metal samples are being run. Operating Tip: Since some samples will adhere to the cups, we recommend that you keep spare cups on hand.
PerkinElmer

Liner Alumina, 100mm3, Pkg.1

Use alumina cups if the sample is to be brought to temperatures higher than 1500°C and when metal samples are being run. Operating Tip: Since some samples will adhere to the cups, we recommend that you keep spare cups on hand.
PerkinElmer

Autosampler Aluminum Sample Pans (covers not included), 30µL, 0.1mm, Vented, Pkg.400

The Autosampler sample pans are used to prepare sample materials for the Pyris 1 Autosampler, DSC 7 RS and DSC-4 RS. Pans are available in sealed or vented versions. These pans may also be used for non-robotic systems. Vented. 1 bar maximum internal pressure. Require Covers (B0143003).
PerkinElmer

Auto sampler Aluminum Sample Covers (pans not included), 0.1mm, Pkg.400

The Autosampler sample pans are used to prepare sample materials for your DSC Autosampler. Pans are available in sealed or vented versions. These pans may also be used for non-robotic systems. For use with (B0143015, B0143016, B0143017, B0143018, and B0143019).
PerkinElmer

Aluminum Sample Pans, Volume: 12.5 microliters, Pkg.100

Tubing Adapters and Connectors provide a means to connect the component to the screw fittings of the PTFE tubing assemblies or to connect tubing components.

Sample Holder Cover Reforming Tool

DSC performance is enhanced with sample holder covers that are formed properly and not degraded by extended usage. This tool allows the analyst to reform the platinum covers to their original dimensions.

TUBE- RND TYGON R3603 0.25 ID

Included with NexION Interface Torch overflow Drain Assembly (N8140506).

Volatile Aluminum Sample Pans and Covers, Pkg.400

These aluminum pans and covers have a temperature range of -170°C to 600°C, 20 µL volume, maximum pressure of 2 bar. Compatible with our crimpers and sealers (02190061 or B0139005 with B0144637). 400 per pack.

Stainless Steel Pans, Covers and O-Rings, Pkg.1000

Under no circumstances should the capsules be heated above 300° C. Any application requiring the heating beyond 200° C or where gaseous decomposition products may be generated should first be tested outside of the instrument. Always use guard ring inserts in conjunction with the sealed capsules. Stainless Steel Pans, Covers and O-Rings, Pkg.1000

Tygon Tubing, Clear

0.95 cm (.374 in.) i.d. x 1.27 cm (0.5 in.) o.d. per foot. For aqueous solutions only.

"热分析" 1-50188 产品与服务

每页